AirFit N20 for Her

Sizing the AirFit N20

To comfortably fit a broader range of patients, AirFit N20 features an entirely new cushion design. To make crosswalking your existing patients easier, we recommend using our sizing guide – included in each AirFit N20 box and specifically designed to help patients find the right fit.

You can also download a copy of our sizing guide here.

The sizing guide has three cut-outs: small, medium and large. Find the size that most comfortably accommodates your patient.The modular design of AirFit N20 means each size cushion easily clicks into the same mask frame.

 

Fitting the AirFit N20

  1. Unclip EasyClick Magnets.
  2. With your patient holding the mask towards their face, slide the headgear over the back of their head.
  3. Reclip EasyClick Magnets.
  4. Once your patient’s headgear and mask are properly fitted, you can use the upper and lower headgear straps to help fine-tune their fit. The upper headgear straps provide most of the adjustment. The lower headgear straps can be used to gently tighten a patient’s mask.
    For additional information on mask maintenance and care, you can also visit the Supporting your patients section for more videos.

Fitting the AirFit N20

  1. Unclip the EasyClick Magnets.
  2. With the mask held against your face, pull the headgear over your head.
  3. Bring each of the magnets up to meet their corresponding clips on the frame.
  4. Adjust the tabs on the upper headgear.
  5. Adjust the tabs on the lower headgear.
  6. With your device still switched off, connect your device tubing to your mask elbow.
  7. Connect the elbow to your mask.
  8. Switch on your therapy device.

Managing leak with your AirFit N20

  1. Leak often occurs when your mask’s seal is compromised by movement, incorrect fitting or improper sizing.
  2. To find a source of leak, run your finger along the edge of your mask’s seal. Once located, adjust your headgear.
  3. Resolve any leak in the upper part of your mask by adjusting your upper straps.
  4. Resolve lower mask leak with your lower straps.
  5. If leak persists, reseal by briefly pulling your mask away from your face and letting your cushion reinflate.
  6. If leak continues, you may need a different size mask. Try our sizing guide or speak to your healthcare provider about getting a different size mask.

Cleaning your AirFit N20 (Daily)

  1. Disassemble mask.
  2. Soak cushion, elbow and short tubing in warm water (approximately 86°F/30°C) with mild liquid detergent for up to ten minutes. To ensure a thorough clean, shake components in water.
  3. Clean components with a soft-bristle brush.
  4. Rinse components under warm water. Inspect each component to ensure that each is clean and free of detergent residue. Wash and rinse again, if necessary.
  5. Leave mask components to air dry out of direct sunlight.

Cleaning your AirFit N20 (Weekly)

  1. Disassemble mask. EasyClick Magnets can remain attached to headgear during cleaning.
  2. Soak frame and headgear in warm water (approximately 86°F/30°C) with mild liquid detergent for up to ten minutes. To ensure a thorough clean, shake frame and headgear in water.
  3. Rinse both components in clean water. Squeeze each repeatedly to ensure detergent is fully removed. Inspect each component to ensure that each is clean and free of detergent residue. Wash and rinse again, if necessary.
  4. Squeeze each component repeatedly to remove excess water.
  5. Leave both components to air dry out of direct sunlight.

How to Disassemble

  1. Print your ResMed sizing guide. Remember to print to scale.
  2. Trim your guide from the paper.
  3. Using a mirror, hold your sizing guide to your face. The top of the guide should correspond with the highest part of tour nose bridge—just between your eyes.
  4. The lower part of the guide indicates which mask size is best for your face. The size that aligns just below your lower lip will be your best fit.

How to Reassemble

  1. Print your ResMed sizing guide. Remember to print to scale.
  2. Trim your guide from the paper.
  3. Using a mirror, hold your sizing guide to your face. The top of the guide should correspond with the highest part of tour nose bridge—just between your eyes.
  4. The lower part of the guide indicates which mask size is best for your face. The size that aligns just below your lower lip will be your best fit.

Haircare Tips for AirFit N20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

These instructions are for general information purpose only. For full details consult the user guide.

Helpful resources
For additional therapy assistance.

More support

ResMed garanti oplysning for alle produkter
Looking for ResMed warranty information on your mask, CPAP device or other ResMed product? Find the answers to your ResMed warranty questions
Following up on your treatment
With your therapy underway and equipment set up, the one last and important step of this journey is following up on your treatment. Here’s what you need to know.
Setting up your equipment
Tips and guidelines to set up your therapy equipment correctly.
Ved at fortsætte med at gennemse denne side, giver du samtykke til, at cookies kan benyttes. Vi bruger cookies til at give dig den bedst mulige oplevelse på vores hjemmeside. Skift indstillinger eller læs mere. eller Læs mere

Administrer dine præferencer vedrørende cookies

Vælg venligst om vores hjemmeside kan bruge krævede og / eller statistiske / marketing cookies, som forklaret nedenfor:

Påkrævede cookies

Disse cookies er essentielle for at hjemmesidens funktioner kan fungere.

Analytiske cookies

Disse cookies giver ResMed mulighed for at analysere brugen af hjemmesiden for at måle og forbedre ydeevnen.

Reklame Cookies

Disse cookies bruges til at hjælpe med at annoncere bedre afhængigt af dine interesser.