Produkt koder:

Device only:
Lumis 100 VPAP S (28004)
Lumis 100 VPAP St (28104)
Lumis 100 VPAP ST-A (28201)
Lumis 150 VPAP ST (28115)
Lumis 150 VPAP ST-A (28205)

Device with heated humidifier & heated tube:
Lumis 100 VPAP S (28003)
Lumis 100 VPAP ST (28103)
Lumis 150 VPAP ST (28114)
Lumis 150 VPAP ST-A (28204)

 

Personlig ventilation er let

iVAPS + AutoEPAP

Lumis 100 technical specifications

  • CPAP
  • S
  • T
  • ST with optional iBR
  • PAC
  • iVAPS*** (with iBR) and optional AutoEPAP
  • Delivered pressure: 
    • Lumis 100 VPAP S & VPAP ST:
      2–25 cm H2O (S mode)
      4–20 cm H2O (CPAP mode)
    • Lumis 100 VPAP ST-A:
      2–30 cm H2O (S, T, ST and PAC modes)
      4–20 cm H2O (CPAP mode)
  • Respiratory rate: 5–50 bpm
  • Supplemental oxygen: Recommended maximum flow: 15 L/min
  • Alarms (Lumis 100 VPAP ST-A only)
  • Vsync
  • TiControl™
  • Trigger and cycle
  • Ramp
  • Ramp Down
  • Climate Control Auto
  • Essentials mode
  • SpO2 monitoring
  • Built-in wireless connectivity to AirView**
  • ResScan
  • Weight:
    • Lumis 100 VPAP S & VPAP ST
      1106 g (device only)
      1268 g (device with HumidAir humidifier)
    • Lumis 100 VPAP ST-A
      1238 g (device only)
      1336 g (device with HumidAir heated humidifier)
  • Dimensions (L x W x H):
    116 mm x 205 mm x 150 mm (device only)
    116 mm x 255 mm x 150 mm (device with HumidAir heated humidifier)
  • DC power supply: 24V/3.75A
  • Sound pressure levels: 26.6 dBA with uncertainty of 2 dBA as measured according to EN ISO 17510-1:2009 (CPAP mode)
  • Aircraft use

Lumis 150 technical specifications

  • CPAP
  • S
  • T
  • ST with optional iBR
  • PAC
  • iVAPS*** (with iBR) and optional AutoEPAP
  • Delivered pressure:
    • Lumis 150 VPAP ST:
      2–25 cm H2O (S, T, ST, PAC and iVAPS modes)
      4–20 cm H2O (CPAP mode)
    • Lumis 150 VPAP ST-A:
      2–30 cm H2O (S, T, ST, PAC, iVAPS modes)
      4–20 cm H2O (CPAP mode)
  • Respiratory rate: 5–50 bpm
  • Supplemental oxygen: Recommended maximum flow 15 L/min – (CPAP, S, T, ST, PAC); 4 L/min (iVAPS)
  • Alarms (Lumis 150 VPAP ST-A only)
  • Vsync
  • TiControl™
  • Trigger and cycle
  • Ramp
  • Ramp Down
  • Climate Control Auto
  • Essentials mode
  • SpO2 monitoring
  • Built-in wireless connectivity to AirView**
  • ResScan
  • Weight:
    • Lumis 150 VPAP ST:
      1106 g (device only)
      1268 g (device with HumidAir humidifier)
    • Lumis 150 VPAP ST-A:
      1238 g (device only)
      1336 g (device with HumidAir heated humidifier)
  • Dimensions (L x W x H):
    116 mm x 205 mm x 150 mm (device only)
    116 mm x 255 mm x 150 mm (device with HumidAir heated humidifier)
  • DC power supply: 24V/3.75A
  • Sound pressure levels: 27-30 dBA with uncertainty of 2 dBA as measured according to ISO 80601-2-70:2015 (CPAP mode)
  • Aircraft use

References:
* Not available with Lumis 100 VPAP S.
** AirView also supports a card-to-cloud option for more detailed data via the SD card.
*** iVAPS therapy mode is indicated for patients weighing 30 kg and above.

 

Spørgsmål?